Skip to main content
Medix East Africa Limited — Your Medical Solutions Provider

Blood Banking

Blood Bank Refrigerator BBR-4V296

296-litre blood bank refrigerator holding 4±2°C with forced-air cooling, 0.1°C accuracy and full alarm monitoring.

Blood Bank Refrigerator BBR-4V296BBR-4V296

Overview

The BBR-4V296 is the main storage refrigerator in a blood bank, holding whole blood and red cell concentrate at 4±2 degrees C — the 2 to 6 degrees C band required for safe red cell storage. A microprocessor controller holds temperature to 0.1 degree C accuracy with uniformity within 1.5 degrees C, so there are no warm corners, and forced-air refrigeration on CFC-free R134a cools the cabinet to 5 degrees C within 70 minutes even in a 32 degree C room, recovering to 6 degrees C within 15 minutes of a door opening.

The interior is stainless steel for easy cleaning after a blood spill, and the exterior carries an anti-bacterial coating. An electrically heated glass outer door stays frost-free so stock can be read without opening, and three transparent acrylic inner doors mean only one basket is exposed at a time, cutting cold loss by around 70 per cent. Four adjustable shelves and twelve baskets hold up to 156 blood bags of 450ml, on castors.

Audio and visual alarms cover high and low temperature, sensor failure, system failure, door ajar, and power loss.

Medix East Africa supplies the blood bank refrigerator model bbr- 4v296 with pre-installation site assessment, delivery, installation and commissioning by our own biomedical engineers, and acceptance testing before handover. Operator training is delivered to the staff who will use it day to day, and technical training is available for your biomedical department.

After handover we hold genuine spare parts for the equipment we supply, run preventive maintenance under annual contract, and respond to faults across Kenya and the wider East African region. Pricing is issued by formal quotation, because it depends on configuration, quantity, delivery terms and warranty.

Need pricing for the Blood Bank Refrigerator BBR-4V296?

Email the sales team, or ask us on WhatsApp right now.

Key features

  • Audio and visual alarms cover high and low temperature, sensor failure, system failure, door ajar, and power loss
  • Four adjustable shelves and twelve baskets hold up to 156 blood bags of 450ml, on castors for placement in a blood bank or transfusion laboratory
  • Installed and commissioned by Medix biomedical engineers
  • Operator training delivered at handover
  • Genuine spare parts held locally
  • Preventive maintenance available under annual contract

Technical specifications

ModelBBR-4V296
Capacity296 litres — up to 156 blood bags of 450 mL
Temperature4±2°C (2–6°C)
Accuracy0.1°C; uniformity ≤1.5°C
CoolingForced air, R134a CFC-free
Recovery≤15 min to 6°C after door opening
InteriorStainless steel
DoorsHeated glass outer door, 3 acrylic inner doors
AlarmsHigh/low temperature, sensor, system, door ajar, power failure
ManufacturerSupplied by Medix East Africa
CategoryBlood banking
InstallationSite assessment, installation and commissioning by Medix engineers
TrainingOperator training delivered at handover
SupportPreventive maintenance and genuine spare parts
CoverageKenya and East Africa

Specifications are as published by the manufacturer and may vary by configuration. Confirmed specifications are stated on your formal quotation.

Clinical applications

  • Hospital laboratories
  • Diagnostic centres
  • County health facilities
  • Medical training institutions

Frequently asked questions

Medix East Africa issues pricing by formal quotation rather than publishing it online, because equipment price depends on configuration, quantity, delivery location and warranty terms. Email sales@medixafrica.com with the quantity you need, send a WhatsApp enquiry to 0113894809, or call +254 726 022122.
Yes. Medix biomedical engineers carry out site assessment before delivery, install and commission the equipment on site, run acceptance testing, and hand over with documentation. Installation is part of the supply for major equipment rather than a separate charge.
Yes. Operator training for the clinical staff who will use the equipment is delivered at handover, and technical training is available for your in-house biomedical department. Refresher training can be arranged when new staff join.
Yes. Medix holds genuine spare parts for the Blood Bank Refrigerator BBR-4V296 locally and provides preventive maintenance, corrective repairs and calibration support through its in-house biomedical engineering team. Annual maintenance contracts are available covering scheduled visits, priority response and agreed parts terms.
Lead time depends on whether the configuration is held in local stock or ordered from the manufacturer. Confirmed lead times are stated on every formal quotation, and delivery scheduling is agreed with your facility in advance so that installation can be planned around theatre or laboratory workload.
Email usWhatsApp